Program 01 ENTER NEW USER CODE
Master Code
>
01 User Code ID (eg 05)
>
New Code
(eg 4321)
Result = New code 4321 entered at User Code ID 05
Program 02 SUSPEND USER CODE
Master Code
>
02
>
User Code ID (eg 05)
Result = User Code at ID 05 suspended
Program 03 RESTORE USER CODE
Master Code
>
03
>
User code ID (eg 05)
Result = User Code at ID 05 restored
Program 04 SUSPEND ALL USER CODES
Master Code
>
04
Result = All User Codes suspended
Program 05 RESTORE ALL USER CODES
Master Code
>
05
Result = All User Codes restored
Program 06 SET UNLOCK TIME
Master Code
>
06
>
enter open time (range 2 – 9 secs)
Result = After code entry the lock will unlock for the set time
Program 07 ONE TIME USER CODE
Master Code
>
07
>
enter one time code (eg 4321)
Result = User Code 4321 will only work once and then be removed from memory
Program 08 SET CODE FREE MODE
Master Code
>
08
Result = Lock will be continuously unlocked
Program 09 CANCEL CODE FREE MODE
Master Code
>
09
Result = Lock will revert to normal operation
Program 10 CHANGE MASTER CODE
Master Code
>
10
>
enter length of Master Code followed by new Master Code
(eg 6123456)
>
confirm length of Master code followed by new Master code (6123456)
Result = Master Code now changed to #123456. Note: If the length of the Master Code is
changed then all previous User Codes will be deleted
Program 11 CANCEL EMERGENCY OPEN MODE
Master Code
>
11
Result = The emergency unlocked condition via REM 2 will be cancelled and the lock will revert
to normal operation
Program 12 DELETE ALL USER CODES
Master Code
>
12
>
12 (7 secs)
Result = All User Codes will be cleared from the memory
Code accepted
Code rejected
Code(s) valid
but suspended
The lock memory will store 90 different
User Codes, each identified by a User Code
ID - 01 to 90.
A new code will be rejected if it is already
in the memory.
Codes may be 4, 5 or 6 digits long.
The length of the Master Code determines
the length of the User Codes.
The lock is delivered with the factory set
Master Code #1234
You are advised to change the Master
Code immediately after installation –
(see Program 10)
The Master Code always has the # prefix
When in Programming Mode a Program
Code must be entered within 5 seconds,
otherwise the lock will revert to normal.
The
*
may be used at any time to clear a
wrong entry and revert to normal.
If the Master Code is changed to another
of the same length then all the User
Codes will be retained.
If the Master Code is changed to one of a
different length then all the User Codes
will be deleted.
OPERATING INSTRUCTIONS
UNLOCK TIME The factory pre-set UNLOCK
time is 4 seconds. This may be changed
(see Program 06).
PENALTY TIME Entering 3 incorrect User
Codes will cause the lock to suspend activity for
a penalty time of 10 seconds.
CODE FREE MODE If Code Free Mode is
required on a regular basis then it is advisable
to set it mechanically by key, as follows:
Turn the key clockwise 90 degrees, return it
to the horizontal and remove it. The lever
handle should now retract the latch without
using a code.
To reset the lock to Normal Mode turn the key
90 degrees anti-clockwise, return to horizontal
and remove it. The lever handle will not now
retract the latch without first entering a valid
code. Note that Program 08 may be used to set
the lock into Code Free Mode. If left in this Code
Free Access Mode electronically, the lock can
remain so for up to 18 months.
REVERTING TO FACTORY SETTING If the
Master Code is not known the lock memory can
be cleared and made to revert to the factory
Master Code as follows:
1 Remove one battery
2 Press and hold the 0 button, replace the
battery, the Blue LED will flash twice, beep will
sound twice, then release the 0 button.
3 Within 3 seconds press the * button 3 times
and the Blue LED will flash twice. The lock will
have reverted to the factory set Master Code,
#1234, and all other settings will be erased.
REMOTE RELEASE OPTION The lock has 2
sets of terminals for remote release, labelled
REM 1 and REM 2 on the printed circuit board in
the front housing. Cables are provided with the
lock for these connections.
REM 1 is intended for use where there is a need
to allow a visitor to open the door after having
been identified by intercom or by sight from
within. REM 1 would be connected to a
pushbutton on a reception desk, or to the
appropriate button on an intercom. Pushing the
button would cause the Blue LED to light and
would release the lock for the normal set time.
REM 2 is intended for use where there is a need
for the door to be released by an alarm system,
such as a fire alarm. This enables emergency
personnel to rapidly check that no one is
trapped/overlooked in classrooms, wards, guest
rooms, etc during an emergency evacuation, or
during a fire drill. When activated by an alarm
REM 2 will maintain the unlocked condition for
30 minutes. During this time the red LED will
flash once every second to indicate the
unlocked condition. The lock will automatically
revert to normal after 30 minutes. If required
Program 11 can be used to revert the lock to
normal before the 30 minute period has
finished.
BATTERY POWER The Codelock 5000 should
provide well in excess of 500,000 openings, of
4 seconds each, from 4 x AA cells rated at
2,900 mAh.
LOW BATTERY When the battery power is
low the Red LED will flash 5 times before the
Blue LED flashes to signal acceptance of the
code. Batteries should be changed as soon as
this happens.
CODES PROGRAMMING